Tests Initial Evaluation Post–Vision Therapy Evaluationa
Best-corrected distance visual acuity Right eye: +4.00 sphere (Snellen 20/20)
Left eye: +4.00 sphere (Snellen 20/30)
Right eye: +4.75 sphere (Snellen 20/20)
Left eye: +4.75 sphere (Snellen 20/20-1)
Monocular fixation Visuoscopy: 1∆ nasal, unsteady eccentric fixation (left eye)
Haidinger’s brush: 1∆ nasal eccentric fixation (left eye)
Cover test (with correction) Far: 4∆ constant left esotropia
Near: 2∆ constant left esotropia
Comitancy Cover test in diagnostic action fields: comitant eso-deviation
Extraocular movement test Full range of motion, right and left eyes
Correspondence Worth four-dot: harmonious anomalous correspondence
Bagolini striated lenses: harmonious anomalous correspondence
Hering-Bielschowsky After-Image test: harmonious anomalous correspondence
Synoptophore: harmonious anomalous correspondence
Out-of-instrument evaluation of sensory fusion Stereopsis
Near: nil (Randot Preschool Stereotest)
Stereopsis
Near: 400” random dot stereopsis (Randot Preschool Stereotest)